4" Adapt A Valve™ IC

4" Adapt A Valve™ Inspection Chamber Accessories

Description Product Code Unit Price (CDN)
IC Downstream Debris Plug 04 72AAVDP04 20.00

* Inspection Chamber Accessories C/W Handle End & Stainless Screws




Description Product Code Unit Price (CDN)
IC Test Gate 04 72ATest04 32.00




Description Product Code Unit Price (CDN)
IC Normally Closed
Backwater Valve Cassette
72AAVNC04 72.00


Description Product Code Unit Price (CDN)
IC Normally Opened
Backwater Valve Cassette
72AAVNO04 72.00

* Please note ¾” SCHD 40 Pipe Not Included (for extended handle)

Click here to download a PDF version of brochure.

Click here to download a PDF version of Price List.


New Features Include

  • Our new Adapt a Valve™ Inspection Chamber is constructed to SDR 26 heavy wall sewer specifications which gives it far more strength & stability.
  • Reflective sticker in body serves as a guide for easy cassette or test gate installation.
  • Improved gasket system feature heavier retained gaskets that allow easy insertion.
  • The proven Mainline Adapt A Valve™ cassettes & receiver system is now integrated into the inspection chamber.
  • This system allows the use of a removable & re-insertable pressure test gate, normally opened cassette, or normally closed cas sette for backflow prevention.
  • All cassettes are easily installed or removed from any depth with the extension handle eliminating the need for special tooling.
  • The Mainline Adapt A Valve™ cassette features a revolutionary light weight gate that offers next-to-no flow restrictions. The double hinged gate design keeps the backflow gate aligned for a perfect O-ring seal.

Redesigned lids will accept the ScotchMark™ Electronic Marker System or Ferrous metal disk for easy metal detector use.

Testimonial

WESTERN LINE CLEANING & INSPECTION SERVICES LTD.

5128 242 Street Langley, B.C. V2Z-2M9 Tel: 604 - 532 - 7070

Contractor: BRAY ENTERPRISES October 13, 2010

Location: 160 A STREET NORTH OF 10 AVE, SURREY.

Utility Type: SANITARY

Pipe Size (mm) 200

SECTIONS TESTED : S1 – S2 , & EXISTING MAIN TO IC LOT # 4 ON 10 AVE.

Test Pressure: (P.S.I) 3.5

Length of Test: 5 MINUTES 200mm & 2.5 MINUTES 100mm

Starting P.S.I.: 3.5

Ending P.S.I.: 3.5

Allowable Loss (if applicable)

Actual Loss: NIL

Pressure Loss (P.S.I) NIL

Line ( s ) Passed: YES

Inspector/Tester: MICHAEL A. KLING

Remarks: S1 – S2 LAMPED OKAY

SANITARY SEWER TESTED WITH NEW STYLE IC LOCKING LIDS IN PLACE ( PASSED AIR TEST )